EASY2LOG©
Temperature Logger UHF Semi-Passive Tags
CAEN RFID’s EASY2LOG® Temperature
Logger is a low cost, semi-passive UHF tag that allows to
monitor temperature sensitive products during transportation or
storage. Being compliant to the EPC Class1 Gen2/ISO18000-6C
standards, EASY2LOG® can be used with most of the Gen2 UHF RFID
readers on the market without requiring any additional equipment.
The Logger is configurable either in Continuous or Over-Threshold
logging modes, allowing the storage of up to 8000 temperature
samples with programmable sampling times. Once programmed, the tag
will start to monitor the life of your temperature sensitive
product, thus allowing to identify any problems occurred along the
whole cold chain by just performing an inventory cycle. The
EASY2LOG® temperature logger is recommended for recording
temperatures during transportation and/or storage of
temperature-sensitive goods such as:
- Pharmaceuticals
- Fresh food (fruit, vegetables);
- Seafood;
- Meat and poultry;
- Milk-based products;
- Frozen food;
- Chemical/pharmaceutical
products.
A927z higlights
- EPC C1G2 (ISO18000-6C) Compatible;
- Frequency range: 860 MHz ÷ 928 MHz;
- Read range: approx. 10m in air (2.5m on metal) @ 2W ERP;
- Unique ID plus long EPC code (512 bit);
- Memory capacity: 8000 samples (16 kbyte);
- Programmable sampling interval;
- Programmable temperature thresholds;
- Battery life: 3 or 5 years;
- Temperature range: -20°C to +70°C;
- ±0.1°C Accuracy (typical);
- No calibration required;
- Dimensions: 130.4x23.4x12.7 mm3;
- Battery charge measurement through RF.
RT0005 higlights
- EPC C1G2 (ISO18000-6C) Compatible;
- Frequency range: 860 MHz ÷ 928 MHz;
- Read range: approx. 10m in air (2.5m on metal) @ 2W ERP;
- Unique TID plus long EPC code (512 bit);
- Memory capacity: 4k samples (8 kByte);
- Multiple programmable sampling interval;
- Multiple programmable temperature thresholds;
- Multiple programmable alarms;
- Temperature Histogram function;
- Mean Kinetic Temperature calculation;
- Remaining Shelf Life calculation;
- Easy to use manual interface;
- Typical usage time: 1 year;
- Temperature range: -20°C to +70°C;
- Accuracy : ±0.1°C (typical);
- Battery charge status monitoring through RF or manual
interface.
|